C CommandsC Commands
LASAIR II Operator’s ManualLASAIR II Operator’s Manual
PagePage
G-3G-3
C CommandsC Commands
Supported C CommandsSupported C Commands
C 0 yyC 0 yy Set Date-Year. Two digit yearSet Date-Year. Two digit year
C 1 mmC 1 mm Set Date-MonthSet Date-Month
C 2 ddC 2 dd Set Date-DaySet Date-Day
C 3 hhC 3 hh Set Time-HourSet Time-Hour. Use 24 . Use 24 hour format.hour format.
C 4 mmC 4 mm
Set Set Time-MinuteTime-Minute
C 5 secC 5 sec Set Time--SecondSet Time--Second
C 6 id_stringC 6 id_string Set Instrument IDSet Instrument ID
C 7 numC 7 num Set Number of SamplesSet Number of Samples
C 8 hhC 8 hh Set Sample Time-Hour. Set sample time in order of Set Sample Time-Hour. Set sample time in order of hours, minutes andhours, minutes and
seconds to avoid problems.seconds to avoid problems.
C 9 minC 9 min
Set Sample Time-Minutes. Set sample time in order of hours,Set Sample Time-Minutes. Set sample time in order of hours,
minutes and seconds to avoid problems.minutes and seconds to avoid problems.
C 10 secC 10 sec Set Sample Time-Seconds. Set sample time in order of hours,Set Sample Time-Seconds. Set sample time in order of hours,
minutes and seconds to avoid problems. This commanminutes and seconds to avoid problems. This command returns a Range Errord returns a Range Error
if sec < 6, and min = 0, and hours = 0.if sec < 6, and min = 0, and hours = 0.
C 11 [1/0]C 11 [1/0]
Set Sample Print on/offSet Sample Print on/off
C 12 hhC 12 hh Set Delay Time--Hours. Set delay between samples.Set Delay Time--Hours. Set delay between samples.
C 13 minC 13 min Set Delay Time--Minutes. Set delay between samples.Set Delay Time--Minutes. Set delay between samples.
C 14 secC 14 sec
Set Delay Time--Seconds. Set delay between samples.Set Delay Time--Seconds. Set delay between samples.
C 16 [1/0]C 16 [1/0]
Set continuous (repeat) mode on/off. When turned off, the numberSet continuous (repeat) mode on/off. When turned off, the number
of samples is set to 1.of samples is set to 1.
C 21 chan nameC 21 chan name Set Analog ID Label. Set name for user analog channel 1-4Set Analog ID Label. Set name for user analog channel 1-4
C C 22 22 chan chan minmin Set Analog 4 mA value. Set user analog channel minimumSet Analog 4 mA value. Set user analog channel minimum
engineering unit value.engineering unit value.
C C 23 23 chan chan maxmax
Set Analog 20 mA value. Set user analog channel maximumSet Analog 20 mA value. Set user analog channel maximum
engineering unit value.engineering unit value.
C 24 chan unitsC 24 chan units Set Analog Units. Set name for analog channel units.Set Analog Units. Set name for analog channel units.
C 25 chan [1/0]C 25 chan [1/0]
Enable/disable analog channelEnable/disable analog channel
C 32 hhC 32 hh
Set Purge Delay Time HoursSet Purge Delay Time Hours

Table of Contents

Other manuals for Particle Measuring Systems LASAIR II 550L

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Particle Measuring Systems LASAIR II 550L and is the answer not in the manual?

Particle Measuring Systems LASAIR II 550L Specifications

General IconGeneral
BrandParticle Measuring Systems
ModelLASAIR II 550L
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals