EasyManua.ls Logo

Paytec Eagle - Service Mode - Coin Diagnostics

Paytec Eagle
95 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
85
Table 3
Service mode – coin diagnostics
When a coin is not recognized with ‘Service mode’ enabled in Fn23, the message INH** is displayed on EAGLE
LCD followed by a number.
Table 3 contains a list of error messages.
Error
Possible solutions
INH 1
Unidentified Check EAGLE configuration
INH 2
EAGLE in Exact-Change condition
Fn03: check the option Coin no.** Exact-
Change = Y/N”
INH 3
Euro coin rejected because EAGLE is configured
in NCU
Fn03: check the option “Coin Euro? Y
Select “N” to accept coins
INH 4
nonEuro coin rejected because EAGLE is
configured in Euro (=978)
Fn03: check the option “Coin Euro? N”
Select “Y” to accept coins
INH 5
No key has been inserted (but option “Coin
No.** with Cashless = Y”)
Fn03: check the option “Coin No.** with
Cashless? N”. Select “Y” to accept coins
INH 6
Key inserted but cannot be recharged Pull out the key and then reinsert it
INH 11
Key inserted whose credit is higher than the max.
credit
Fn00: check “Maximum credit cashless=___;
modify the value
INH 12
Current credit is higher than max. price
programmed
Fn04: check “Price max *****”
INH 13
Current credit is higher than max. price
programmed
Fn00: check “Maximum credit with cash=.*****;
modify the value
INH 14
Key cannot be recharged
Fn15: check “Inhibit reload Cashless? Y”.
Select “N” to accept
INH 15
Coins are only accepted when a key has been
inserted
Fn00: check option “Coins only with Key? N”.
Select “Y” to accept
INH 16
TestServiceKey inserted Fn15: check option “Coins and bills test?”
INH 17
General ServiceKey inserted (key with blocs, …)
Insert a compatible user key
INH 18
EAGLE in free vend mode Fn07: check time bands for free vends
INH 19
Current credit is higher than 65535 Limit credit
INH --