4. System sizing
4.1. Recommendations
4.1.1. Injector/DLFC/BLFC-Valve configuration
Note
For upflow configuration, it is highly recommended to use the injector cap 61923-20,
equipped with a pressure regulator.
4.2. Sizing a softener (single unit)
4.2.1. Parameters to be considered
Whenever installing a softener, it is preferable to have full water analysis to ensure the inlet water
content will not affect the resin bed.
Note
Please consult your resin manufacturer specifications to ensure that no additional
pretreatment prior to softening is required.
Valve
type
Tank
diameter
Resin
volume
Injector DLFC BLFC
[in] L DF Color UF Color [gpm] DF [gpm] UF [gpm]
5810/
1650
8 9 - 21 00 Violet 000 Brown 1.5
0.25 0.259 22 - 28 0 Red 00 Violet 2.0
10 29 - 42 1 White 0 Red 2.4
12 43 - 56 2 Blue 1 White 3.5
0.50 0.50
13 57 - 70
3 Yellow 2 Blue
4.0
14 71- 85 5.0
16 86 - 113 4 Green 3 Yellow 7.0
21 114 - 198
5 Grey 4 Green
10.0
1.00 1.00
24 199- 283 15.0

Table of Contents