Installer Manual Fleck 5810 - SXT - Programming
Ref. MKT-IM-016 / C - 08.06.2018 53 / 106
6.2. Commands
6.3. Setting the time of the day (TD)
Set the time in the system.
Regeneration cycles: → B1: First backwash (for dF2b regeneration mode);
→ B2: Second backwash (for dF2b regeneration mode);
→ BD: Brine draw;
→ BF: Brine fill;
→ BW: Backwash;
→ LC: Last cycle (for "other" regeneration mode);
→ RF: Refill (for "other" regeneration mode);
→ RR: Rapid rinse;
→ SP: Service position (for "other" regeneration mode);
→ SR: Slow rinse (for "other" regeneration mode);
→ SV: Service position for brine preparation (for "UFFF"
regeneration mode).
2. Data display
3. PM indicator → Appears if controller set in US unit.
4. Flow indicator → Flashes when outlet flow is detected.
5. x1000 indicator → Appears when the displayed number is bigger than 9999.
6. Programming icon → Appears in programming modes.
7. Service icon → Appears in service mode;
→ Flashes if a regeneration cycle has been queued.
8. Error /
Information icon
→ Appears in case of error, see page 96, or in diagnostic mode, see
page 71.
A Press to pass to the next step.
B Use and to adjust the values.
A Press and hold or until the programming icon replaces the service
icon and the parameter display reads TD.
B Set the time with or .
C Press to validate the selection and return to the service mode, or wait
for 10 seconds.