Installer Manual Fleck 5810 - SXT - Programming
62 / 106 Ref. MKT-IM-016 / C - 08.06.2018
6.5.9. Feedwater hardness (H)
Set the feedwater hardness.
Note
The feedwater hardness parameter is only available if the regeneration control type has
been programmed for volumetric regeneration.
Mandatory
Enter the feedwater hardness in °TH or ppm for softener system.
Note
The feedwater hardness can be set from 1 to 1999 °TH or ppm.
6.5.10. Reserve selection (RS)
Select the type of reserve.
Note
The reserve selection parameter is only available if the regeneration control type has been
programmed for volumetric regeneration.
Note
cr is only available if the regeneration control type has been programmed for volumetric
delayed regeneration.
Options:
SF: Safety factor, in % of initial capacity;
rc: Fixed reserve capacity (fixed volume in L);
cr: Variable reserve capacity.
Q Press or to set the feedwater hardness in accordance with display
format (DF), see chapter 6.5.3. Display format mode (DF), page 59.
R Press to validate the selection and to move the next parameter.
S Press or to select the type of reserve.
T Press to validate the selection and move to the next parameter.