EasyManua.ls Logo

Pentair FLECK 5810 SXT - Regeneration Failure; Memory Error; Fail Safe Error

Pentair FLECK 5810 SXT
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installer Manual Fleck 5810 - SXT - Troubleshooting
Ref. MKT-IM-016 / C - 08.06.2018 97 / 106
10.2.3. Regeneration failure
Note
The system has not regenerated for more than 99 days or 7 days if the regeneration control
type has been set to day of week.
10.2.4. Memory error
Note
The controller board has a memory failure.
10.2.5. Fail safe error
Note
The valve has failed to find position in one minute.
A Perform a manual regeneration to reset the error code.
B If the system is metered, verify that it is measuring flow by running service
water and watching for the flow indicator on the display.
C If the unit doesn’t measure flow, verify that the meter is working properly
and its cable is well connected.
D Enter master programming mode.
E Verify that the unit is configured properly.
F Check that system capacity has been set properly.
G Check that day override is set properly.
H Check that meter is identified correctly.
I Correct the setting as necessary.
A Perform a hard reset.
B Reconfigure the system via master programming mode.
C Step the valve through a manual regeneration.
D If the error reoccurs, unplug the unit.
E Put it into bypass.
F Contact dealer.
A Unplug the unit and plug back in.
B If the error reoccurs, unplug the unit.
C Put it into bypass.
D Contact dealer.

Table of Contents

Other manuals for Pentair FLECK 5810 SXT

Related product manuals