Installer Manual Fleck 5810 - SXT - Programming
64 / 106 Ref. MKT-IM-016 / C - 08.06.2018
6.5.11. Days override (DO)
Set the maximum number of days between regeneration cycles.
Note
This parameter allows to set the maximum amount of days that the system can stay in
service mode without a regeneration.
Mandatory
In time clock mode the setting of this parameter is mandatory.
Note
Setting the parameter to "OFF" disables this function.
Note
The number of days can be set from OFF, or 1 to 99 days.
Note
This parameter is not displayed for the day of week regeneration.
6.5.12. Regeneration time (RT)
Set the regeneration time.
Note
Regeneration time is the time of the day when regenerations occur for meter delayed
regeneration, time clock regeneration, day of the week regeneration and calendar override
regeneration.
Y Press or to set the days override.
Z Press to validate the selection and move to the next parameter.
AA Press or to set the regeneration time.
AB Press to validate the selection and move to the next parameter.