Installer Manual Fleck 5810 - SXT - Maintenance
88 / 106 Ref. MKT-IM-016 / C - 08.06.2018
9.2.7. Injector cleaning
No. Operation
A Remove the injector block clip (1) using a flat screwdriver on the dedicated slot (2).
B Remove the injector cap (6) using a flat screwdriver on the dedicated slot (7).
C Using the injector block clip (1), remove the injector (8).
Caution
To avoid any damage on the injector, use only the clip to remove it.
D Remove the screen (4) using pliers.
E Using the injector block clip (1), remove the injector plug (3).
F Clean or change the injector (8), the screen (4), the injector plug (3) and the seal (5).
G Lubricate all seals with approved silicone lubricant only.
H Reverse above procedure steps to rebuild.