EasyManua.ls Logo

PEP Modular Computers Modular Computers RS485 - Smadcenableconversion

Default Icon
320 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SMART I/O Users Manual
March 12, 1996
©1996 PEP Modular Computers GmbH
Page 5 - 52
Chapter 5 Analog Modules
5.2.8.15 SMADCEnableConversion
Syntax
error_code SMADCEnableConversion(u_int8 PortNr, u_int8
channel, BOOLEAN enable);
Description
This function checks if an SM-PT100 board is fitted on the specified port and
if the channel is valid and forces the HW task to convert the raw values. If
the flag enable is TRUE (<>0), then conversion of raw values to degrees
Celsius is executed, else if (enable=FALSE) no conversion takes place. The
function invalidates converted data, if enable is set to FALSE.
Input
u_int8 PortNr
Port number to enable data conversion
(from 0 to 10)
u_int8 channel
Number of specified channel (0 to 3)
BOOLEAN enable
Flag for enabling or disabling conversion of
raw values
Output
error_code SUCCESS
E_MNF
If wrong type of module or no module
is fitted on the selected port
E_PARAM
If wrong channel number is specified
E_BMODE
If conversion can’t be enabled because
a bad or no sensor type is specified
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
Example
RetVal = SMADCEnableConversion(0, 1, FALSE);

Table of Contents