EasyManua.ls Logo

PEP Modular Computers Modular Computers RS485 - Smdac1 Deinit

Default Icon
320 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SMART I/O Users Manual
October 01, 1996
©1996 PEP Modular Computers GmbH
Page 5 - 122
Chapter 5 Analog Modules
5.5.8.10 SMDAC1DeInit
Syntax
error_code SMDAC1DeInit(u_int8 PortNr);
Description
This function deinitialises the SM-DAC1 Module on the port PortNr by
freeing the resources tied up with it and shuts down the outputs.
Input
u_int8 PortNr
SM-Port number to de-initialise
(from 0 to 10)
Output
error_code SUCCESS
E_SEEK if module not initialised
or standard OS-9 error code (refer to the OS-9
Technical Manual Error Codes Section).
Example
RetVal = SMDAC1DeInit(0);

Table of Contents