SMART I/O Users Manual
©1996 PEP Modular Computers GmbHMarch 12, 1996 Page 6 - 15
Chapter 6 Communications Modules
6
modify the settings, for example:-
$ xmode baud=19200 cs=7 par=none /scc3
<return>
check that the system has taken the parameters:-
$ xmode/scc3
<return>
/scc3
noupc bsp bsl echo if null=0 pause pag=24 bsp=08
del=18 eor=0D eof=1B reprint=04 dup=01 psc=17 abort=03
quit=05 bse=08 bell=07 type=00 baud=19200 xon=11
xoff=13 tabc=09 tabs=4
refer to the OS-9 help page for parameter descriptions by using the follow-
ing:-
$ xmode -?
<return>
and finally initialise the device:-
$ iniz scc3
<return>

Table of Contents