Percul Lapcom S Separate 100 - No. 15: Throttle Position Calibration

Percul Lapcom S Separate 100
58 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter No.
Sensor output upper limit:
Less than 5V
Indicator
Press and hold the SE
T
key for 2 seconds when
the steering wheel is
turned to the left.
The indicator mark
moves to the left side.
Use within a sensor output range of 0.01 – 4.99.
In general, do not use a displacement sensor that exceeds 5 k.
No. 15: Calibration for Throttle position
These settings are used for measuring the throttle position.
* Press the CLEAR key and display parameter No. 15.
1. Install the throttle position sensor onto the vehicle and connect the sensor to the
LAPCOM unit. Verify that the “TEACH” indicator is flashing. The indicator mark is
at the bottom. If “TEACH” is not flashing, the LAPCOM unit does not recognize
the sensor. Check the connection and turn the power off/on.
2. Press and hold the SET key for 2 seconds when the throttle is closed.
-37-