Example Description Status Message
F01SSEN1
Enable screen saver.
F01SSEN1
F01SSEN0
Disable screen saver.
F01SSEN0
F01SSEN2
Toggle screen saver enabled state.
F01SSENx , where x is 0 or 1 depending on the current
enabled state of the scrren saver.
F01SSEN?
Query screen saver enabled state.
F01SSENx , where x is 0 or 1 depending on the current
enabled state of the scrren saver.
8.132. SSSTART -- Set Idle Time Required for Screen Saver to
Start
This command sets or queries the amount of time (in milliseconds) that the front panel buttons must be idle
before the screen saver starts.
This command is an integer command. See
Section 6.2 for more information on this type of command. The
minimum and maximum values for this command are 500 and 600000, respectively.
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message
F01SSSTART2000
Set screen saver start time to 2
seconds (2000 ms).
F01SSSTART2000
F01SSSTART>500
Increase screen saver start time by
0.5 seconds (500 ms).
F01SSSTARTx , where x is the new value of the
screen saver start time. If this command was issued
after the example above, then the status message
would be F01SSSTART2500 .
F01SSSTART?
Query screen saver start time.
F01SSSTARTx , where x is the new value of the
screen saver start time. If this command was issued
after the example above, then the status message
would be F01SSSTART2500 .
8.133. SSTEXT -- Set Text to be Displayed by Screen Saver
This command sets or queries the text messages displayed by the screen saver. The arguments of this command
are the screen number, the line number, and the text to be displayed. The screen number must be between 0
and 3. It indicates which message screen we are trying to set or query. Each message screen consists of two
lines of text that can be up to 16 characters long. The second number indicates which line of the message we
are tring to set or query. The line number must be 0 or 1 corresponding to the first and second line, respectively.
Finally, the text argument is the actual text that will be displayed on the LCD. If the text is '?', then a query will
be performed. If the text empty, then the message will be cleared. If both message lines are cleared for a given
screen, then that screen will not be displayed by the screen saver. If all screens have been cleared, then the
screen saver will never start (although it is easier just to use the
SSEN command for this).
This command is saved to non-volatile memory only as part of a preset. The state of this command will be
restored after power-up only if a preset is saved and that preset is set to be the power-on preset.
Example Description Status Message

Table of Contents

Other manuals for Polycom Vortex EF2280

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2280 and is the answer not in the manual?

Polycom Vortex EF2280 Specifications

General IconGeneral
Rack capacity1U
Frequency range20 - 20000 Hz
Cancellation span270 ms
Echo cancellation65 dB
Phantom power48 V
Nominal input level0 dB
Output gain-100 - 20 dB
Output impedance33 Ω
Maximum output amplitude23 dB
RS-232 ports1
Audio connections2 x 3.5mm
Parallel ports quantity2
Input voltage110 - 240 V
Output current20 mA
Output voltage5 V
Input frequency47/63 Hz
Power consumption (typical)30 W
Operating temperature (T-T)0 - 40 °C
Weight and Dimensions IconWeight and Dimensions
Weight1800 g
Dimensions (WxDxH)483 x 244 x 45 mm