EasyManuals Logo

Polycom Vortex EF2280 User Manual

Polycom Vortex EF2280
105 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
8.120. PRESETL -- List All Commmands in a Preset
8.121.
PRESETP -- Set Which Preset Will Be Activated At Power-Up
8.122.
PRESETQ -- Execute a Preset Quietly
8.123.
PRESETW -- Save a Preset
8.124.
PRESETX -- Execute a Preset
8.125.
REFASGN -- Assign AEC Reference to Input Channel
8.126.
REFGAIN -- Set Reference Output Gain
8.127.
SGGAIN -- Set Gain of Signal Generator
8.128.
SGMUTE -- Mute Signal Generator
8.129.
SGTYPE -- Set Type of Signal Produced by Signal Generator
8.130.
SSDELAY -- Set Delay Between Screen Saver Screens
8.131.
SSEN -- Enable or Disable Screen Saver
8.132.
SSSTART -- Set Idle Time Required for Screen Saver to Start
8.133.
SSTEXT -- Set Text to be Displayed by Screen Saver
8.134.
SWRESET -- Perform Soft Reset of System
8.135.
SWVER -- Query Software Version
8.136.
VTXMODI -- Enable VTX Mode on Specified Inputs
8.137.
VTXMODO -- Enable VTX Mode on Specified Inputs
1. Introduction
This document describes the command protocol that is used to communicate with the Vortex EF2280 via its RS-
232 port.
2. RS-232 Hardware
The communication between the Vortex and a host controller is conducted via the RS-232 port on the back panel
of the Vortex. The Vortex's RS-232 port operates at the following settings:
Bit Rate (bps): 9600 (default), 19200, or 38400
Data Format: 8 data bits, no parity, 1 stop bit (8N1)
Flow Control: none (default) or hardware (RTS, CTS)
Note that although the flow control setting is user selectable to none or hardware, hardware flow control must be
used when updating the firmware of the Vortex. This means that while a 3-wire RS-232 cable (RX, TX, GND) is
acceptable for control of the Vortex, the minimum cable for updating firmware should contain 5 wires (RX, TX,
RTS, CTS, GND).
3. Programming Tips
3.1. Initialization
During power up of the Vortex device or initialization of the host program, electrical fluctuations on the RS-232
lines may cause the Vortex to receive spurious data. After initialization, the host program should send a few
carriage return characters (^M, ASCII 13) to the connected Vortex to flush out any spurious characters it may
have received. Failure to do this could result in the Vortex ignoring the first command received after initialization.
As part of the host program initialization, the host will want to synchronize the status of its controls with the
current status of the Vortex devices that are being controlled. The host could initialize its controls to default

Table of Contents

Other manuals for Polycom Vortex EF2280

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2280 and is the answer not in the manual?

Polycom Vortex EF2280 Specifications

General IconGeneral
Rack capacity1U
Frequency range20 - 20000 Hz
Cancellation span270 ms
Echo cancellation65 dB
Phantom power48 V
Nominal input level0 dB
Output gain-100 - 20 dB
Output impedance33 Ω
Maximum output amplitude23 dB
RS-232 ports1
Audio connections2 x 3.5mm
Parallel ports quantity2
Input voltage110 - 240 V
Output current20 mA
Output voltage5 V
Input frequency47/63 Hz
Power consumption (typical)30 W
Operating temperature (T-T)0 - 40 °C