8.39. DSPAUTO -- Enable Automatic DSPLOAD Status Messages
This command sets or queries whether or not DSPLOAD messages will be automatically generated whenever the
DSP utilization changes.
This command is a boolean command. See
Section 6.1 for more information on this type of command.
Example Description Status Message
F01DSPAUTO1
Enable automatic DSPLOAD messages.
F01DSPAUTO1
F01DSPAUTO0
Disable automatic DSPLOAD messages.
F01DSPAUTO0
F01DSPAUTO2
Toggle automatic DSPLOAD messages.
F01DSPAUTOx , where x is 0 or 1 depending on
the current setting of the DSPAUTO paramter.
F01DSPAUTO?
Query the value of the DSPAUTO
parameter.
F01DSPAUTOx , where x is 0 or 1 depending on
the current setting of the DSPAUTO paramter.
8.40. DSPLOAD -- Query Percentage of Variable DSP Resources
Used
This command queries the current percentage used of the available variable DSP resources. When this number
reaches 100 percent, no more variable DSP veatures may ben enabled. An 'ERROR#060' will be generated if a
command attempts to exceend 100 percent utilization.
If the
DSPAUTO feature is enabled, then a DSPLOAD status message will be generated automatically any time the
percent utilization changes.
Example Description Status Message
F01DSPLOAD?
Query percentage of variable DSP resources
used.
F01DSPLOADx , where x is between 0 and 99 and
indicates the percentage of the variable DSP
resources being used.
8.41. ERROR -- Enable or Disable Error Messages
This command sets or queries whether or not error messages for non-fatal errors are reported via RS-232 and
the digital bus.
If an error is generated and error messages are enabled, a status message will be automatically generated of the
form 'F01ERROR#xxx ', where xxx is a three digit number indicating the error code. The following table lists the
non-fatal error messages that can be generated by the Vortex.
Error Number Description
ERROR#001
Unrecognized command.
ERROR#002
Syntax error in command.
ERROR#004
Attempt to change parameter that is locked via
NVLOCK or FPLOCK.
ERROR#005
Attempt to unlock
NVLOCK or FPLOCK, but invalid password given.

Table of Contents

Other manuals for Polycom Vortex EF2280

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom Vortex EF2280 and is the answer not in the manual?

Polycom Vortex EF2280 Specifications

General IconGeneral
Rack capacity1U
Frequency range20 - 20000 Hz
Cancellation span270 ms
Echo cancellation65 dB
Phantom power48 V
Nominal input level0 dB
Output gain-100 - 20 dB
Output impedance33 Ω
Maximum output amplitude23 dB
RS-232 ports1
Audio connections2 x 3.5mm
Parallel ports quantity2
Input voltage110 - 240 V
Output current20 mA
Output voltage5 V
Input frequency47/63 Hz
Power consumption (typical)30 W
Operating temperature (T-T)0 - 40 °C
Weight and Dimensions IconWeight and Dimensions
Weight1800 g
Dimensions (WxDxH)483 x 244 x 45 mm