The P62, P80, and P82 CPA Event Log provides the same error code data found in the P10,
P30, and P30i Error Log in addition to the event date & time stamp information. The "CPA
ERROR" identifier in the error code output message indicates that this is a machine fault error
code that can be used along with the
Error Code Troubleshooting Guide
to help resolve the
issue.
Typical CPA Event Log data:
l Error Code Data
o
Event Time & Date Stamp
o
Error Code Number
o
Error Code Description
o
Odometer
o
Hours
o
Motor Current*
o
.Input Line Current*
o
Input line voltage*
o
Buss Voltage*
o
OEM Factory only data
Note: * machine dependent parameter.
Removing Error Codes:
Unlike the Error Log used on P10, P30, and P30i, you cannot manually delete (clear) error
codes from the CPA Event Log (or Event Log).