ASL State DESCRIPTION
due.
Yellow Solid Indicates an error has occurred, was self-corrected and the machine can
be used. The fault can be cleared.
Yellow Pulsing There is a current non-recoverable fault condition, there is a loss of a
major function and the machine is out-of-service. Machine service is
required.
ASL Settings and Functions
Setting the ASL light brightness level
The ASL Light Brightness level settings are HIGH, MEDIUM, and LOW. On P10, P30, and
P30i consoles, the light brightness level can be switched OFF.
l On P10, P30, and P30i consoles, the OFF setting switches the ASL light brightness
OFF for all ASL state conditions. Setting the ASL Light Brightness OFF only switches
the ASLlight brightness OFF and not the ASL active status functionality.
l Regardless of the brightness level setting (including OFF), you can view the current
ASL state (blue, yellow, etc.) in the service access menus, see "Viewing the current
ASL state" on the next page.
P62, P80, and P82 consoles:
Access Hardware Validation (51765761) > Maintenance menu > AS LIGHT
BRIGHTNESS > select HIGH, MED, or LOW.
Disabling the ASL Maintenance Reminder
When set to ON, the ASL maintenance reminder - pulsing blue light state is triggered ON
when the maintenance counter counts down to zero miles (or zero hours). When set to OFF,
the ASL Maintenance Remindercounter is ignored and the ASL state is not changed to
pulsing blue.
l The "OFF" setting effectively disables the ASL "blue pulsing" state without affecting the
yellow or pulsing yellow fault states.
l When set to OFF, the Maintenance Reminder counter continues counting down the
miles (or hours) remaining which can be viewed in the service access menu, see "View-
ing the current ASL state" on the next page.
l Error code events will still affect the ASL state condition even when the Maintenance
Reminder is set to OFF.
P62, P80, and P82 consoles:
Access Club Settings (5651565) > Maintenance menu > Maintenance Reminder > select
ON or OFF.