resultshowing on displaykey
shows following menuMenu↓
shows following value/settingvalue/setting
shows following setting valuesetting to be changed
shows previous menuMenu↑
shows previous value/settingvalue/setting
shows previous setting valuesetting to be changed
shows value/settingMenuEnter
makes change to settingvalue setting
confirms value setsetting to be changed
shows software version numberMenuEsc
shows menuvalue/setting
stops change to setting without savingsetting to be changed
In order to prevent anyone from accidentally changing settings, all menus with the exception of
Measurements and Display are protected. This protection can be removed by first selecting the “Enter”
key, followed by the “ ↑” key and holding this key combination for a minimum of 3 seconds. When
protection is removed, the double brackets surrounding <<MENU>> will change to >>MENU<<. When
this has changed, the menu can be activated by pressing the “Enter” key.
Protection is automatically re-activated after 15 minutes. However, it can be re-activated manually
by “Esc” ; the name of the menu will then be shown normally again.
Examples of operation
When the weighing indicator display is not in use, the Nett weight is shown.
This is the actual weight of the water in the substrate slabs. By entering the “ ↓ ” key , the
following setting is displayed: # of Load Cells . You will now be shown how the Groscale has
been calibrated.
By pressing “ ↓ ” when the display shows Nett weight , the following items are shown respectively:
• Nett weight (is updated 3 times per second)
• # of Load Cells (# represents number of cells)
• Tare Weight
• Saturated Slab
• Max #kg/5V
Examples of settings changes
In the Display menu, the display contrast can be set as well as the language in which the settings
should be shown. Please note that the values are still in Dutch decimal numbers. The menu
appears when “Esc” is pressed, followed by the “↓ ” key. The menu choices or settings are:
• Contrast
• Language select
111Installing Priva Compass - 00.014
Groscale