Measuring error at
0.1 mS
Measuring error at 5
mS
Measuring error at 10
mS
Measuring error at 15
mS
Cable length (2x 0.34
mm²)
--0.3%0.5%1%5 m
0.1%3%6%9%60 m
0.1%6%11%16%120 m
Measuring error at
0.1 mS
Measuring error at 5
mS
Measuring error at 10
mS
Measuring error at 15
mS
Cable length (4x 0.34
mm²)
--0.1%0.3%0.4%5 m
--1.5%3%5%60 m
0.1%3%6%9%120 m
Specifications for EC sensor
Angled EC sensor with
NTC and thermistor
Angled EC sensor,
long, with NTC 1
kΩ/25°C
Inline EC sensor with
NTC and thermistor
Inline EC sensor, short,
with NTC 1 kΩ/25°C
Article description
3779045
This part is no longer
available.
37790413779043
This part is no longer
available.
3779052Article number
NTC 1 kΩ/25 °C
Thermistor 3 kΩ/25 °C
NTC 1 kΩ/25 °CNTC 1 kΩ/25 °C
Thermistor 3 kΩ/25 °C
NTC 1 kΩ/25 °CTemperature sensors
-NTC 1k with cable, long
EC sensor (3476074)
-NTC 1k with cable,
short EC sensor
(3476073)
Spare parts
0.01 to 15 mS/cm0.01 to 15 mS/cmMeasurement range
1.82 cm/cm
2
1.23 cm/cm
2
Cell factor
Necessary approx. 1.8 to 2.2 %/°CNecessary approx. 1.8 to 2.2 %/°CTemperature
compensation
0 to 45 °C (when active)
0 to 65°C (when inactive)
0 to 45 °C (when active)
0 to 65°C (when inactive)
Temperature range
Maximum 6 barMaximum 10 barPressure range
0.5 to 25 m
3
/hour0.5 to 25 m
3
/hour
Flow speed
Calibrating the EC measurement (Compass)
Have the EC sensor calibrated by a dealer at least once a year. The calibration can be done using a
portable EC meter. Use the portable EC meter to determine the EC value of the water within the
sensor.
A portable reference EC meter is required for calibrating the EC measurement, like Portable
EC and pH analyzer (3779190) or Portable EC analyzer (3779191).
Installing Priva Compass - 00.01494