EasyManua.ls Logo

Priva Compass User Manual

Priva Compass
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Manual
> INSTALLING PRIVA COMPASS

Table of Contents

Questions and Answers:

Priva Compass Specifications

General IconGeneral
BrandPriva
ModelCompass
CategoryFarm Equipment
LanguageEnglish

Summary

About This Manual and Safety

Safety Precautions

Provides essential safety rules for working with the product and maintaining it.

Electrical Safety Procedures

Details critical safety instructions for electrical connections and component handling.

Installation Steps Overview

General Installation Process

Outlines the initial steps for installing the Compass system and its software.

Field Equipment Installation

Step-by-step guide for installing and connecting various field equipment.

Compass System Commissioning

Commissioning Preparation and Software

Details requirements for commissioning, including latest software versions.

Priva Network Setup

Explains the setup of the industrial Priva network and its separation from the office network.

Gateway Configuration

Guides on setting up the Gateway via Wi-Fi or wired connection and software updates.

Troubleshooting and VDC Reset

Common System Malfunctions and Solutions

Lists common problems and their possible causes and solutions.

Resetting the VDC Power Supply

Procedure for resetting the VDC power supply if 24 VDC is not outputting.

Connecting Field Equipment

Field Equipment Wiring Guidelines

General rules for connecting field equipment and using 24 VDC power supply.

Priva Blue ID Hardware Connections

System Component Connectivity

Lists connections for C4 controller and MX34 module (power, I/O, RS485, etc.).

Priva Weather Station WSC11

Weather Station Integration and Measurements

Overview of the WSC11's capabilities and measurements for horticulture.

Weather Station Data and Positioning

Optimal Weather Station Location

Guidelines for selecting the best location for representative weather measurements.

Meteorological Station

Meteorological Station Overview

Describes the Meteorological station's design for optimal weather sensor positioning.

Weather Interface WI2

WI2 Purpose and Installation

Explains the WI2's role in connecting sensors and its splashproof housing.

WI2 Sensor Specifications

Setting WI2 Jumpers for Sensors

Guides on setting jumpers for Linear light and Radiation sensors.

Linear Light Sensor LS2 and LS2WI

Linear Light Sensor Principle

Explains how the light sensor measures sunlight intensity.

Rain Sensor RD2WI

Rain Sensor Functionality

Explains how the RD2WI sensor detects rain and its limitations.

Wind Direction Sensor WDS2WI

Wind Direction Sensor Principle

Explains how the sensor determines wind direction and its output signal.

Wind Speed Sensor WSS2WI

Wind Speed Sensor Principle

Explains how the sensor generates pulses based on wind speed.

Outside Temperature Sensor OTS2

Outside Temperature Sensor Principle

Explains the sensor's use of an NTC resistor for temperature measurement.

Flow Sensor

Flow Sensor Connecting

Explains how to connect the flow sensor to record volume flow.

pH Interface

Dosing Channel Driver

EC-DSS Interface

Drain Water Sensor

Groscale System Overview

Groscale Commissioning

Initial Commissioning Steps

Covers checking operation, setting load cell data, and calibration.

Setting Load Cell Data

Procedure for entering load cell sensitivity and zero point data.

Troubleshooting Groscale Issues

Weighing Indicator Display Issues

Common problems with the weighing indicator and their solutions.