350 ... 1100nmSpectral range
Spectrum for global irradiance sensor (Source: data
sheet for component TEMD5080X01 / VISHAY)
Precipitation
Ceramics, capacitive measurement, sensor area heatedType
1 / 0 (precipitation yes/no)Measuring range
0.1 WThermal output, sensor dry, bedewing protection
1.1 WThermal output, sensor wet, drying phase
Temperature
PT1000Type
-30 +60 °CMeasuring range
0.1 °CResolution
±1 °C (-5 +25 °C)Accuracy with wind speed >2m/s
Air pressure sensor
PiezoresistiveType
300 1100 hPaMeasuring range
0.01 hPaResolution
±0.5 hPa at 20°CAccuracy
±0.1 hPa / yearLong-term stability
Relative humidity
CMOS capacitiveType
0 100 % rel. humidityMeasuring range
0.1 % rel. humidityResolution
±10% rel. humidity at 20°CAccuracy with wind speed >2m/s
Absolute humidity
0 ... 400 g/m3Measuring range
0.01 g/m3Resolution
Dew-point temperature
-30 ... +60 °CMeasuring range
0.1 °CResolution
Inside temperature of housing
Silicon sensorType
-30 +60°CMeasuring range
0.1 °CResolution
±2 °CAccuracy
Digital interface
RS485Type
Half-duplex modeMode
115200Baud rate
MODBUS RTUData format
Accessories
WSC11 Connection cableArticle description
3779241Article number
15 mLength
Cable with cable socket on device side and open ends on reception
side.