To pin VDE cable Contact Relay
1 yellow N/O (normally open) other relay
4 green C (common) other relay
3 white N/O (normally open) Pacing relay
2 brown C (common) Pacing relay
9.2.6.4 "Current output plus relay" output (identity code C)
A relay combined with a current output can be ordered as an option. The
relay either switches as a fault indicating relay in the event of a fault on the
pump and with "Liquid level low 1st stage" warning messages and "Liquid
level low 2nd stage" fault messages or is used as a pacing relay.
The behaviour is factory-programmed. If another switching function is
desired, the pump can be reprogrammed in the
‘Relay’
menu.
The variable to be signalled for the current output can be selected in the
‘ANALOG OUTPUT’
menu.
The current output plus relay can be retrofitted and operates once it is
plugged into the board.
Electrical interface
for current output
Data Value Unit
Open circuit voltage: 8 V
Current range: 4 ... 20 mA
Ripple, max.: 80 μA ss
Load, max.: 250
for semiconductor switch ("relay"):
Data Value Unit
Max. residual voltage at I
off max
= 1 µA 0.4 V
Maximum current 100 mA
Maximum voltage 24 VDC
Pacing pulse duration, approx. 100 ms
Identity code 4
2
3
1
4
P_G_0073_SW
Fig. 23: Assignment on pump
P_SI_0044
Fig. 24: Assignment on cable
Installation, electrical
37