3 Supplementary Operating Instructions for Modbus RTU
3.1 About this Modbus pump............................................ 40
3.2 Control elements......................................................... 41
3.3 Electrical installation................................................... 42
3.4 "Modbus RTU" implementation................................... 43
3.4.1 "Modbus RTU" message structure.......................... 44
3.5 Device monitoring....................................................... 46
3.6 Emergency mode........................................................ 46
3.7 Faults.......................................................................... 46
3.8 Accessories................................................................ 47
3.9 Modbus RTU for Prominent pumps register............... 47
3.9.1 "Device identification" register.................................
48
3.9.2 "Modbus" register.................................................... 48
3.9.3 "Production data pump module-specific" register.... 49
3.9.4 "Current operating parameters" register.................. 50
3.9.5 "Setpoint operating parameter" register................... 54
3.9.6 "Advanced configuration" register............................ 56
3.9.7 "Accessories 1" register........................................... 61
3.9.8 "Accessories 2" register........................................... 61
3.9.9 "Accessories 3" register........................................... 62
3.9.10 "Debugging data" register...................................... 63
3.1 About this Modbus pump
Solenoid metering pumps gamma/ X with "Modbus RTU" connec‐
tion differ from standard pumps by the connecting option to a
"Modbus RTU" bus system. A "Modbus RTU" pump gamma/ X can
either be connected to a "Modbus RTU" bus or be used stand-
alone.
Example:
n Measured value-dependent metering of sodium-calcium hypo‐
chlorite into a swimming pool water circuit, where the pump is
controlled by a PLC Programmable Logic Controller in
‘Modbus RTU’
operating mode.
A "Modbus RTU" version of the gamma/ X (identity code feature
"Control option" = M) is intended for integration into a "Modbus
RTU" system.
This document contains general information for the implementation
of the metering pump gamma/ X GMXa into the serial communica‐
tion protocol of the Modbus RTU.
Supplementary Operating Instructions for Modbus RTU
40

Table of Contents

Other manuals for ProMinent gamma/ X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent gamma/ X and is the answer not in the manual?

ProMinent gamma/ X Specifications

General IconGeneral
Protection classIP65
Max. Pressure25 bar
Power supply100-230 V, 50/60 Hz
Material of pump headPVDF, Stainless steel
Temperature range-10 °C to +45 °C
TypeDiaphragm dosing pump
Stroke lengthAdjustable
Stroke frequencymax. 180 strokes/min
Materials in contact with the mediumPVDF, PTFE, stainless steel
ControlManual, external control via contacts or 0/4-20 mA signal
Control OptionsExternal, potential-free contacts, 0/4-20 mA
Dosing Accuracy±2%