Page #5 background imageLoading...
Page #5 background image
CAUTION!
Change the temporary
‘password’
in the pump
menu under
‘Settings
è
Service
è
Password’
.
CAUTION!
Only download the "gamma /X" app from the
Google Play Store - not from other sources.
CAUTION!
Do not modify the device.
In particular do not increase the size of the aerial.
Personnel must:
n Be familiar with Android smart devices.
n Have read and understood the pump operating instructions and
these operating instructions as well.
The Bluetooth metering pump can be operated licence-free in the
following countries:
Belgium, Denmark, Germany, Estonia, Finland, France, Greece,
Great Britain, Ireland, Italy, Canada, Latvia, Lithuania, Luxem‐
bourg, Malta, the Netherlands, Norway, Austria, Poland, Portugal,
Sweden, Switzerland, Slovakia, Slovenia, Spain, Czech Republic,
Hungary, USA and Cyprus.
CAUTION!
For all other countries:
Check whether the operation of Bluetooth metering
pumps is permitted in the country in question.
Please get in touch with the ProMinent head office.
WARNING!
The Bluetooth metering pump is not designed for
applications in which interference from or by the
metering pump can lead to fatal injury or serious
personal injury.
WARNING!
The Bluetooth metering pump can cause interfer‐
ence to or even destroy radio and television fre‐
quencies.
It is essential that this is avoided.
For a remedy, refer to the "Troubleshooting"
chapter.
Qualification of personnel
Licences for Bluetooth metering
pumps
Emissions
Supplementary Operating Instructions for Bluetooth Control
5

Table of Contents

Other manuals for ProMinent gamma/ X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent gamma/ X and is the answer not in the manual?

ProMinent gamma/ X Specifications

General IconGeneral
Protection classIP65
Max. Pressure25 bar
Power supply100-230 V, 50/60 Hz
Material of pump headPVDF, Stainless steel
Temperature range-10 °C to +45 °C
TypeDiaphragm dosing pump
Stroke lengthAdjustable
Stroke frequencymax. 180 strokes/min
Materials in contact with the mediumPVDF, PTFE, stainless steel
ControlManual, external control via contacts or 0/4-20 mA signal
Control OptionsExternal, potential-free contacts, 0/4-20 mA
Dosing Accuracy±2%