Q24/Q48 Tape Library Installation and Operations Manual
Error
Code
Description
User Action
Critical Component Status
C0
Network initialization
failed
Check network cable and
network configuration. If
the error recurs, contact
technical support
Library controller probably defective.
Probably a hardware problem, check
library controller
C1
Telnet Interface
initialization failed
Check network cable and
network configuration. If
the error recurs, contact
technical support
Library controller probably defective.
Probably a hardware problem, check
library controller
C2
Web server
initialization failed
Check network cable and
network configuration. If
the error recurs, contact
technical support
Library controller probably defective.
Probably a hardware problem, check
library controller
C6
Ping command did not
reached target
Check network cable and
network configuration. If
the error recurs, contact
technical support
Library controller probably defective.
Probably a hardware problem, check
library controller
C7
Cannot Upgrade from
USB
Retry of Firmware
upgrade, if not successful
contact technical support
Library controller probably defective.
Probably a hardware problem, check
library controller
C8
Cannot Upgrade from
FTP
Retry of Firmware
upgrade, if not successful
contact technical support
Library controller probably defective.
Probably a hardware problem, check
library controller
C9
Cannot Upgrade Media
changer from Flash
Retry of Firmware
upgrade, if not successful
contact technical support
Library controller probably defective.
Probably a hardware problem, check
library controller
D0
ROM error.
ROM checksum
incorrect
Retry of Firmware
upgrade, if not successful
contact technical support
Library controller probably defective.
Probably a hardware problem, check
library controller
D1
RAM error.
Power on Self Test (
POST ) has failed,
Retry operation; after
several occurrences
contact technical support
Library controller probably defective.
RAM defect, check library controller
D2
NVRAM error.
R/W operation to
NVRAM has failed
Retry operation; after
several occurrences
contact technical support
Library controller probably defective.
Probably a hardware problem, check
library controller
D3
CTC Error.
Timer unit has failed
during POST.
Retry operation; after
several occurrences
contact technical support
Library controller probably defective.
Probably a hardware problem, check
library controller