1017
10.2.3 OpenFlow Controller
Specify up to five IP addresses to which the switch should establish an OpenFlow Controllers
connection. Each command invocation specifies one IP address and connection mode (TCP or TLS). If
the IP Port is omitted then the default IP port number 6633 is used. The default connection mode is TLS.
Syntax
controller <ipaddr> [<portid>] [ssl | tcp]
no controller {<ipaddr> [<portid>] | all }
Default Setting
SSL
Command Mode
OpenFlow Instance Mode
10.2.4 OpenFlow Hybrid Mode
To configure the hybrid OpenFlow.
Syntax
hybridmode {per-vlan | per-port}
Default Setting
None
Command Mode
OpenFlow Instance Mode