243
5.3.7 SNMP Inform Commands
5.3.7.1 snmp-server host <host-addr> informs
This command configures informs to be sent to the specified host.
Syntax
snmp-server host <host-addr> informs version {2 <community> | 3 <username> [auth | noauth | priv]}
[filter <filtername>] [udp-port <1-65535>] [retries <0-255>] [timeout <1-300>]
no snmp-server host <host-addr>
<host-addr> - The IPv4 or IPv6 address of the host to send the inform to.
<community> - Community string sent as part of the notification. The range is 1 to 20 characters.
version 1 - Sends SNMPv1 informs.
version 2 - Sends SNMPv2 informs.
version 3 - Sends SNMPv3 informs.
<username> - Username of SNMPv3.
auth - Enables authentication but not encryption.
noauth - No authentication or encryption. This is the default.
priv - Enables authentication and encryption.
<filtername> - The filter name to associate with this host. Filters can be used to specify which
informs aresent to this host. The range is 1 to 30 characters.
<udp-port> - The SNMP Inform receiver port. The default is port 162.
<retries> - The number of times to resend an Inform. The default is 3 attempts. The range is 0 to 255
retries.
<timeout> - The number of seconds to wait for an acknowledgement before resending the Inform.
The default is 15 seconds. The range is 1 to 300 seconds.
no - This command deletes inform receivers.
Default Setting
None