UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
QuantaMesh | Switching Commands
607
5.23.2.4 queue cos-queue strict
This command activates the strict priority scheduler mode for each specified queue on a "per-port" basis.
Syntax
queue cos-queue strict <queue-id-0> [<queue-id-1> <queue-id-7>]
no queue cos-queue strict <queue-id-0> [<queue-id-1> <queue-id-7>]
no - This command restores the default weighted scheduler mode for each specified queue on a
"per-port" basis.
Default Setting
None
Command Mode
Interface Config.
This command activates the strict priority scheduler mode for each specified queue on a device.
Syntax
queue cos-queue strict all <queue-id-0> [<queue-id-1> <queue-id-7>]
no queue cos-queue strict all <queue-id-0> [<queue-id-1> <queue-id-7>]
no - This command restores the default weighted scheduler mode for each specified queue on a
device.
Default Setting
None
Command Mode
Global Config.