UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
QuantaMesh | Switching Commands
68
5.2.1.10 storm-control flowcontrol
This command enables 802.3x flow control for the switch.
802.3x flow control only applies to full-duplex mode ports. If PFC feature is enabled on the
same interface, 802.3x flow control will be disabled internally.
Syntax
storm-control flowcontrol
no storm-control flowcontrol
no - This command disables 802.3x flow control for the switch.
Default Setting
Disabled
Command Mode
Global Config
This command enables 802.3x flow control for the specific interface.
802.3x flow control only applies to full-duplex mode ports. If PFC feature is enabled on the
same interface, 802.3x flow control will be disabled internally.
Syntax
storm-control flowcontrol
no storm-control flowcontrol
no - This command disables 802.3x flow control for the specific interface.
Default Setting
Disabled
Command Mode
Interface Config
5.2.1.11 shutdown
This command is used to disable a port.