UANTA COMPUTER INC.
Layer 2/3/4 Managed Switch
QuantaMesh | Switching Commands
93
5.2.3.16 switchport ingress-filtering
This command enables ingress filtering. If ingress filtering is disabled, frames received with VLAN IDs
that do not match the VLAN membership of the receiving interface are admitted and forwarded to ports
that are members of that VLAN.
Syntax
switchport ingress-filtering
no switchport ingress-filtering
no - This command disables ingress filtering. If ingress filtering is disabled, frames received with
VLAN IDs that do not match the VLAN membership of the receiving interface are admitted and
forwarded to ports that are members of that VLAN.
Default Setting
Disabled
Command Mode
Interface Config
This command enables ingress filtering for all ports. If ingress filtering is disabled, frames received with
VLAN IDs that do not match the VLAN membership of the receiving interface are admitted and
forwarded to ports that are members of that VLAN.
Syntax
switchport ingress-filtering all
no switchport ingress-filtering all
all - All interfaces.
no - This command disables ingress filtering for all ports. If ingress filtering is disabled, frames
received with VLAN IDs that do not match the VLAN membership of the receiving interface are
admitted and forwarded to ports that are members of that VLAN.
Default Setting
Disabled
Command Mode
Global Config