Communications Protocol CubiScan 110-T Command Set
CubiScan 110-T 63
Length
15+
Length
6
Length
6
StreamBegin:Thiscommandisexecutedfirst.Itinitializesastreamingfiletransfer.
Command
Description
Command
Packet
Acknowledge
Description
Acknowledge
Packet
Nack
Description
Neg.Ack.
Packet
StartByte
<STX>
StartByte
<STX>
StartByte
<STX>
Command
(p)
Command
(p)
Command
(p)
Stream
(S)
Ack
(A)
Nack
(N)
FileName
SeePutFileTable
Comma
(,)
FileSize
(0000000000)‐(99
99999999)
EndBytes
<ETX><CR><LF>
EndBytes
<ETX><CR><LF>
EndBytes
<ETX><CR><LF>
Length
27+
Length
6
Length
6
StreamData:Thiscommandisexecutedsecond.Itstreamsthefiledata.
Command
Description
Command
Packet
Acknowledge
Description
Acknowledge
Packet
Nack
Description
Neg.Ack.
Packet
StartByte
<STX>
StartByte
<STX>
StartByte
<STX>
Command
(p)
Command
(p)
Command
(p)
Stream
(D)
Ack
(A)
Nack
(N)
FileData
BinaryData
EndBytes
<ETX><CR><LF>
EndBytes
<ETX><CR><LF>
EndBytes
<ETX><CR><LF>
Length
6+
Length
6
Length
6
Putfiletable:
Cs1x0.bin–Sendsafirmwarefile.
Cs1x0par.txt–Sendsaparameterfile.
Measure:
Causestheinstrumenttoinitiateandcommunicateameasurement.Thisisa
non‐legalfortrademode.
Command
Description
Command
Packet
Acknowledge
Description
AcknowledgePacket Nack
Description
Neg.Ack.
Packet
StartByte
<STX>
StartByte
<STX>
StartByte
<STX>
Command
(M)or(C)
Command
(M)
Command
(M)
Ack
(A)
Nack
(N)
CubiScanOR
Host
(C)or(H)
CubiScanor
Host
(C)or(H)
LocationID
(000000)–(ZZZZZZ)
Measureor
Zero
(M)or(Z)
Comma
(,)
Length
(L000.0)–(L999.9)
Comma
(,)
Width
(W000.0)–(W999.9)
Comma
(,)
Height
(H000.0)–(H999.9)