EasyManua.ls Logo

Quantronix CubiScan 110-T - Expanded Communication Protocol

Quantronix CubiScan 110-T
92 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Communications Protocol CubiScan 110-T Command Set
CubiScan 110-T 68
EXPANDED COMMUNICATION PROTOCOL
Length
5
Length
6
Length
6
Measure
Expanded:
Causestheinstrumenttoinitiateandcommunicateameasurement.Thisisa
legalfortrademode.
Command
Description
Command
Packet
Acknowledge
Description
Acknowledge
Packet
Nack
Description
Neg.Ack.
Packet
StartByte
<STX>
StartByte
<STX>
StartByte
<STX>
Command
(M)or(C)
Command
(M)
Command
(M)
Ack
(A)
Nack
(N)
CubiScanOR
Host
(C)or(H)
CubiScanor
Host
(C)or(H)
LocationID
(000000)–
(ZZZZZZ)
Measureor
Zero
(M)or(Z)
Comma
(,)
PackageCount
(0000)‐(9999)
Comma
(,)
Year
(2000)‐(9999)
BackSlash
(/)
Month
(01)‐(12)
BackSlash
(/)
Day
(01)‐(31)
Comma
(,)
Hour
(00)‐(23)
Colon
(:)
Minute
(00)‐(59)
Colon
(:)
Second
(00)‐(59)
Comma
(,)
Length
(L000.00)–
(L999.99)
Comma
(,)
LengthStatus
(00)‐(99)
Comma
(,)
LengthUnits
(in)or(cm)or
(mm)
Comma
(,)
Width
(W000.00)–
(W999.99)
Comma
(,)
WidthStatus
(00)‐(99)
Comma
(,)

Table of Contents