Fig.14 Controls and Checking Components
Emergency buon: If the operator noces a dangerous situaon or simply needs to stop
immediately, he can push the buon and the pile driver will block totally. With the engine
being o and the pump being deacvated, all the funcons in acon will fully stop at
that moment. In that situaon, all the controls are inhibited. The operator has to
unblock the emergency buon, rotate it slowly clockwise, and start the engine again to
regain the normal working condions.
Lighng buon: This buon is placed on the starter frame and must be pushed for the
acvaon of the trac indicator before any movement of the machine. The acvaon of
the indicator is compulsory for the safety in operave areas construcon sites.
Pressure relief valve: The pressure relief valve is placed on the distributor and is set at
the standard working pressure. It intervenes in case of increase of pressure in the
hydraulic circuit, stopping the oil ow and unloads the oil in the tank. The manufacturer
designs the tank gauging levels. The valve is sealed (with red paint or metallic cable) to
avoid adjustment.