EasyManua.ls Logo

Quantum 800 - Changing and Check of the Oil in the Motor Reducers

Quantum 800
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© İnnosis Makine 52
The hydraulic oil tank is equipped with an averaging device for the puricaon of the
contained uid. Such device is provided with a cartridge (lter) with a high ltering power. It
puries the oil on its return to the tank (unloading phase). To check the lter, it is necessary
to remove the lid, unscrew the three screws and extract it from its seat, as showed in gure
30. Use only a new lter of the same type.
Fig 30 Oil lter check
out
IMPORTANT: To avoid polluon, its absolutely forbidden to disperse oils, lubricants, lter
cartridges or other noxious materials in the environment. Comply strictly with the instrucons
in force for the disposal of liquids or solid substances.
2-4 Changing and check of the oil in the motor reducers
Note: every type of motor drive has got plugs placed in dierent angles between each other.
The types placed on the Pile Driver can have an angle of 90° or of 180°, as those showed in
gure 31. Level check
Let the motor drives turn until you bring the plugs in one of the numbers of configuration
1 shown in figure 31(1). In both configurations, plug-in position A represents the
unloading one and must be on about 15° under the white line in the middle of the drive.
The plugin position B represents the loading one. Unscrew both plugs; put oil in the
reducer through plug B, and when the oil comes out of the plug it means that the oil has
reached the right level.