Place the machine on flat ground and check the level and temperature indicator on the
side of the Hydraulic Tanks.
When the oil arrives at half sight (between the blue and red traces, as in figure 29), the
quantity inside the tank is sufficient. But if the oil is nearby the red trace, it will be
necessary to restore it by adding other oil, following the instructions described later.
Fig 29 Level indicator
Replacement
Equip yourself with a container with sucient capacity (200 liters) and place it under the tank
where the unloading plug is situated. Unscrew the loading plug and then the unloading one
while you let the hydraulic oil ow down completely. Following that, screw the loading plug
down aer having substuted the relave gasket. Fill the tank with oil approved by the
Manufacturer. Do this through the loading plug with the help of a funnel. Assuring that the oil
has reached the right point (see gure 29), stop the lling, and screw the plug down.
You should see if the oil reached the right level by looking through the level and temperature
indicator. The oil should be between the red and blue traces, on half sight. It is beer to use the
recommended oil: BP ENERGOL HLP HM 46 or equivalent
Note:
It is advisable to unload the oil when it is hot, so it will come out easier. Therefore, it would be
beer to carry out this operaon at the end of a job.
When you restore the oil level, do not mix dierent types of oil, but always use the same type
as the one contained. It is possible to use a dierent brand, but it must have the same
characteriscs as the one recommended by the Manufacturer.
3.3 Change and check of the hydraulic oil lter in the tank