Operation Quantron E 4
28
When weighing the volume ensure that:
the fertiliser spreader is at a standstill,
the PTO shaft is switched off,
the fertiliser spreader is horizontal and off the ground.
the tractor is at a standstill
the Quantron E is switched on.
Weighing the fertiliser volume in the hopper:
1. Fill the hopper.
A window appears in the display which shows the remaining fertiliser vo-
lume.
2. Highlight the type of filling carried out on the display:
Refill: Continue spreading with the same fertiliser
New fertiliser: Flow factor set to 1.0 and a new flow factor regulation will fol-
low.
ESC Quit
3. Confirm with the Enter button.
The operating screen appears on the display. The weighed quantity can
be superimposed on the display field.
Figure 4.6: Operating screen with weighed quantity
NOTICE
In order to display the remaining fertiliser quantity on the operating screen,
the display option kg left must be selected 4.8.2:
Display config., page 68).