Configurations
16
102-127108955 V1.1 67/ 102
Setting for Full Power applications to meet the normative re-
quirements in the USA.
Parameter Default value
Driving cycle → Acceleration 30
Driving cycle → Creep drive 20
Drive → Opening angle 40
Manual drive → Closing speed 15
Control unit → BDE-M 3-position OFF-A
Control unit → BDE-D → Key-
board
OFF-Mode
Locking → Lock function Always locked
Input → AUX1_IN BEA_Bodyguard
Input → AKA_IN Railbeam
→ USA
Output → AUX1_OUT BEA_Bodyguard
Setting for applications in the USA.
▪ Meets U.S. requirements only in conjunction with the
drive type DFA 127 LE US.
Parameter Default value
Driving cycle → Acceleration 30
Driving cycle → Creep drive 20
Time delays open → Time de-
lay open
5
Drive → Opening angle 40
Manual Drive → Active Sen-
sors
SIS activated
Manual drive → Closing speed 15
Control unit → BDE-M 3-position OFF-M
Control unit → BDE-D → Key-
board
OFF-Mode
Locking → Lock function Always locked
Input → AUX1_IN BEA_Bodyguard
Input → AKA_IN Railbeam
→ USA Low Energy
Output → AUX1_OUT BEA_Bodyguard