UPGRADE
You can check for upgrades for the following items:
Camera: Go to “Upgrade DSMC Firmware” on page 171.
REDMOTE: Go to “Upgrade REDMOTE Firmware” on page 154.
Media: For more information on the media upgrade procedure, see the DSMC Media Operation Guide,
available at www.red.com/downloads.
CALIBRATE
The Calibrate menu includes: Sensor, Gyro/Acc, and Lens.
SENSOR CALIBRATION
Sensor calibration, also known as black shading, is a process during which the camera optimizes image
quality by ensuring that pixel sensitivity remains consistent throughout the sensor. Black shading generates a
calibration map based on system and environment settings. After calibration, the sensor shows a uniform noise
profile over the whole area without any falloffs on any side.
For more information on sensor calibration, see the Black Shading Calibration article, available at www.red.
com/learn/red-101/black-shading-calibration.
NOTE: Calibration maps will still be available after performing a system restore.
CHECK NOISE PROFILE
To check the current noise profile, follow the instructions below:
1. Ensure that the camera reaches the temperature you want to use for your shoot.
2. Set the exposure to the exposure you want to use for your shoot.
3. Put a lens cap on the lens (if a lens is attached) or a front body cap on the BRAIN (if a lens is not attached).
4. Go to Menu > Settings > Look > FLUT.
5. Set FLUT to 8.000.
6. Check the noise that displays on the monitor:
The noise is random, with no fixed patterns or lines. The sensor is calibrated.
The noise has patterns or lines. Calibrate the sensor. For more information, go to “Calibration Capture
(Black Shading)” on page 111.
WHEN TO CALIBRATE SENSOR
Calibration is required:
After an extreme change in temperature (+/– 30°F or +/–15°C) from the current calibration map.
After an extreme change in exposure time (+/– 1/2 sec) from the current calibration map.
If either the T or E in the CAL: T/E indicator is not green.
If the noise profile shows patterns or lines. For more information, go to “Check Noise Profile” on page 110.
For EPIC DRAGON or SCARLET DRAGON: After each firmware upgrade.
For EPIC MYSTERIUM-X or SCARLET MYSTERIUM-X: After a firmware upgrade if instructed to do so in the
firmware release notes.
To check the temperature/exposure of the current calibration file, go to Menu > Settings > Maintenance > System
Status > Calibration.

Table of Contents

Other manuals for RED Epic

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RED Epic and is the answer not in the manual?

RED Epic Specifications

General IconGeneral
SensorMysterium-X
Resolution5120 x 2700 (5K)
Lens MountPL Mount
Frame Rates1-120 fps
Dynamic Range13.5 stops
Recording FormatREDCODE RAW
MediaREDMAG (SSD)
Weight5 lbs (2.3 kg) body only
Sensor Size27.7 mm x 14.6 mm
Operating Temperature32°F to 104°F (0°C to 40°C)

Related product manuals