• SP 5812 1 (Service TEL [Telephone])
• SP 5812 2 (Service TEL [Facsimile])
• SP 5907 (Plug & Play)
• SP 7 (Data Log)
• SP 8 (History)
Use SP 5802 2 (basic machine) or SP 5998 1 (GDI machine) after you have replaced the BICU NVRAM
or when the BICU NVRAM data is corrupted. When the program ends normally, the message "Completed"
shows. When you have replaced the controller NVRAM or when the controller NVRAM data is corrupted,
use SP 5801 1. The message is the same as the basic machine.
With Flash Memory Card
1. Upload the NVRAM data to a flash memory card ( p.161 "NVRAM Data Upload/Download (SP
5824/5825)").
2. Print out all SMC data lists ( p.166 "SMC Print (SP 5990)").
• Be sure to print out all the lists. You have to manually change the SP settings if the NVRAM data
upload ends abnormally.
3. Select SP 5801 2.
4.
Press the OK key.
5. Select "Execute." The messages "Execute?" followed by "Cancel" and "Execute" shows.
6. Select "Execute."
7. When the program has ended normally, the message "Completed" shows. If the program has ended
abnormally, an error message shows.
8. Press the cancel key.
9. Turn the main switch off and on.
10. Download the NVRAM data from a flash memory card (
p.161 "NVRAM Data Upload/Download
(SP 5824/5825)")
Without Flash Memory Card
1. Print out all SMC data lists ( p.166 "SMC Print (SP 5990)").
2. Select SP 5-801 (basic machine) or SP 5998 1
3. Press the OK key.
4.
Select "Execute." The messages "Execute?" followed by "Cancel" and "Execute" show.
5. Select "Execute."
5. System Maintenance
154