No.
Definition
Symptom Possible Cause
634 C
Accounting RAM error
An error is detected in the RAM that
saves the information on the MF
accounting.
Accounting device defective
635 B
Accounting battery error
An error is detected in the battery
that is in
the MF accounting device.
Accounting device defective
670 C
Engine start error
The engine-ready signal is not
issued within 70 seconds after the
switch is turned on.
Engine board defective
Controller defective
Loose connection
692 B
Controller board communication abnormal
Communication error between the
printer part of the controller board
and BICU.
The connector is abnormal between the
controller board and the BICU board.
694
Controller board communication abnormal
Communication error between the
scanner part of the controller
board and BICU.
The connector is abnormal between the
controller board and the BICU board.
760 B
ADF gate abnormal 1
The ADF Gate signal line between
the ADF main
board and the BICU
is disconnected.
ADF main board defective
Input/output board defective
Poor connection (ADF Gate line) between
the ADF main board and the BICU.
761 B
ADF gate abnormal 2
The FGATE signal is not issued from
the ADF within
30 seconds after the
ADF starts feeding.
ADF connector defective
SBU board defective