7807 1
Resets the SC, paper, original, and total jam counters. When the program ends normally,
the message "Completed" is displayed. SP 7807 1 does not reset the following logs: SP
7507 (Display-Paper Jam History) and SP 7508 (Display-Original Jam History).
7808 Reset–Counters
7808 1
Resets all counters except for the management counters. The management counters are
the counters that
are not changed by NVRAM Download (SP 5825 1) When the program
ends normally, the message the message "Completed" is displayed.
7810 Reset–Key Op Code
7810 1
Resets the key operator code. Use SP 7810 1 when the customer has forgotten the key-
operator code. When
the program ends normally, the message "Completed" is displayed,
if the program ends abnormally, an error message is displayed. If the customer forgets the
key operator code. To specify a new key-operator code, use the User Tools: System Settings
Key Operator Tools Key Operator Code On Enter Key Operator Code.
7832* Display-Self-Diag
7832 1
Displays the SC codes and the number of their occurrences. Each number is in the range
of 0 to 9999.
7991*
Dsply–Info Count
Displays the total operating time or the total number of operations. The time is displayed
in the following format: day:hour:minute:second.
7991 1
Dsply–Info Count (Dsply-Timer Count)
The total of the time when the main switch is kept on (excluding the time when the safety
switch is off ( LD Safety Switch).
7991 2
Dsply–Info Count (Dsply-APS Working)
The total of the time when the APS is working.
7991 3
Dsply-Info Count (Dsply-ID S Work)
The total of the time when the ID sensor is working.
7991 4
Dsply-Info Count (Dsply-Dev Counter)
The total number of paper outputs.
SP Mode Tables
47