Bit Switches - 3
SM 103 D418
Fax Option
Type 9001
D418
Communication Switch 02 (SP No. 1-104-003)
No Function Comments
This bit is ignored for memory
transmissions or if ECM is being used.
4-7 Not used Do not change the settings.
Communication Switch 03 (SP No. 1-104-004)
No Function Comments
0-7
Maximum number of page
retransmissions in a G3
memory transmission
00 - FF (Hex) times.
This setting is not used if ECM is switched on.
Default setting - 03(H)
Communication Switch 04 - Not used (do not change the settings)
Communication Switch 05 - Not used (do not change the settings)
Communication Switch 06 - Not used (do not change the settings)
Communication Switch 07 - Not used (do not change the settings)
Communication Switch 08 - Not used (do not change the settings)
Communication Switch 09 (SP No. 1-104-010)
No Function Comments
0-7 IP-Fax dial interval setting
Adjusts the interval of I-fax dialing.
The interval of I-fax dialing is calculated with the
following formula.
[Interval time = specified value with this switch x
0.2 ms]

Table of Contents

Other manuals for Ricoh Aficio MP 8001 SP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ricoh Aficio MP 8001 SP and is the answer not in the manual?

Ricoh Aficio MP 8001 SP Specifications

General IconGeneral
BrandRicoh
ModelAficio MP 8001 SP
CategoryPrinter
LanguageEnglish

Related product manuals