Bit Switches - 3
D418 104 SM
Communication Switch 0A (SP No. 1-104-011)
No Function Comments
0
Point of resumption of memory
transmission upon redialing
0: From the error page
1: From page 1
0: The transmission begins from the page
where transmission failed the previous time.
1: Transmission begins from the first page,
using normal memory transmission.
1-7 Not used Do not change the settings.
Communication Switch 0B (SP No. 1-104-012)
No Function Comments
0-3
Not used
Do not change the settings.
4
Printout of the message when
acting as a Transfer Station
0: Disabled, 1: Enabled
When the machine is acting as a Transfer
Station, this bit determines whether the
machine prints the fax message coming in
from the Requesting Terminal.
5-7 Not used Do not change the settings.
Communication Switch 0C - Not used (do not change the settings)
Communication Switch 0D (SP No. 1-104-014)
No Function Comments
0-7
The available memory
threshold, below which ringing
detection (and therefore
reception into memory) is
disabled
00 to FF (Hex), unit = 4 kbytes
(e.g., 06(H) = 24 kbytes)
One page is about 24 kbytes.
The machine refers to this setting before each fax
reception. If the amount of remaining memory is
below this threshold, the machine cannot receive
any fax messages.
If this setting is kept at 0, the machine will detect