Bit Switches - 4
SM 117 D418
Fax Option
Type 9001
D418
G3 Switch 06 (SP No. 1-105-007)
No Function Comments
1 0 1 0 24.0
1 0 1 1 26.4
1 1 0 0 28.8
1 1 0 1 31.2
Other settings - Not used
Modem types available for reception
The setting of these bits is used to inform the transmitting terminal of the available
modem type for the machine in receive mode.
If V.34 is not selected, V.8 protocol must be disabled manually.
Cross reference
V.8 protocol on/off - G3 switch 03, bit 2
Bit 7 Bit 6 Bit 5 Bit 4 Types
0 0 0 1 V.27ter
0 0 1 0 V.27ter, V.29
0 0 1 1 V.27ter, V.29, V.33
0 1 0 0 V.27ter, V.29, V.17/V.33
0 1 0 1 V.27ter, V.29, V.17/V33, V.34
4-7
Other settings - Not used