Service Call Conditions
D062/D063/D065/D066 3-58 SM Appendix
833 D Self-diagnostic error 8: Engine I/F ASIC
0F30
0F31
ASIC (Mandolin) for system
control could not be detected.
After the PCI configuration, the
device ID for the ASIC could not
be checked.
ASCI (Mandolin) for system control
is defective
Interface between North Bridge and
AGPI is defective
Replace the mother board
0F41
The read/write check done for
resident RAM on the mother
board could not be done
correctly.
Memory device defective
Replace the mother board
50B1
Could not initialize or read the
bus connection.
Bus connection defective, loose
SSCG defective
Replace the mother board
50B2
Value of the SSCG register is
incorrect.
Bus connection loose, defective
SSCG defective
Replace the mother board
834 D Self-diagnostic error 9: Optional Memory RAM DIMM
5101
The write/verify check for the
optional RAM chip on the
engine mother board gave an
error.
Controller defective
Mother board defective
Self-diagnostic Error: Clock Generator
838 D
A verify error occurred when setting
data was read from the clock
generator via the I2C bus.
Replace the controller board