Mechanical Counter (NA Only)
D037/D038/D040/D041 2-66 SM
6. Attach the clamp [A] as shown above.
7. Attach the mechanical counter bracket [B] to the frame ( x 2).
8. Connect the mechanical counter harness [C] to the mechanical counter [D] and the
BCU (CN218) [E], and route the harness as shown above (= x 6)
9. Reassemble the machine.
10. Plug in the machine and turn on the main power switch.
11. Enter the SP mode.
12. Set SP5987-001 to "1: ON".
13. Exit the SP mode, and then turn the machine off and on.