Fusing
D037/D038/D040/D041 4-82 SM
4. Open the paper transfer unit [A]
5. Release the lock levers [B].
6. Hold the fusing unit handles [C], and then pull out the fusing unit.
When installing the fusing unit
Make sure that the both lock levers [B] are locked before closing the duplex unit. Otherwise,
these lock levers [B] can be broken.
4.11.3 ENTRANCE GUIDE PLATE
1. Fusing unit ( Section: Fusing Unit)
2. Entrance Guide Plate [A] ( x 2)
Cleaning Requirement
The entrance guide plate requires cleaning maintenance at every 60 K interval. Clean the
entrance guide plate with a cloth moistened with alcohol at the following points.