Troubleshooting Guide
SM 6-5 D037/D038/D040/D041
Trouble-
shooting
SP No. Max. Min. Title
SP1-801-028 2 -2 Duplex Exit:120 (0.3 default)
2. An error ("1") occurs in the SP1-803-005.
[Setting values of the following SPs + input value with SP1-803-001] > motor speed
adjustable range
e.g.) 1.5 (SP1-801-025) + 1 (SP1-803-001 to -003) = 2.5
In this case, "2.5" is over the maximum adjustable value ("2") of the SP1-801-025. As a
result, the result of the motor speed adjustment issues "1" (error).
Adjust the settings of the SP1-830-001 to -003 so that the total value (motor speed
setting value + input value) is within the adjustable range for each motor described
below.
SP No. Max. Min. Title
SP1-801-025 2 -2 Duplex Entrance:60
SP1-801-027 2 -2 Duplex Exit:60
SP1-801-033 4 -4 Regist Mot:60:1200dpi
SP1-801-034 2 -2 Feed1:CW60:1200dpi
SP1-801-035 2 -2 Feed1:CCW60:1200dpi
SP1-801-036 2 -2 Feed2:CW60:1200dpi
SP1-801-037 2 -2 Feed2:CCW60:1200dpi
SP1-801-038 2 -2 By-pass:60:1200dpi
SP1-801-039 2 -2 Inverter:CW60:1200dpi
SP1-801-040 2 -2 Inverter:CCW60:1200dpi
SP1-801-041 6 -6 FusingMot:60:1200dpi
SP1-801-042 4 -4 BkOpcDevMot:60:1200dpi
SP1-801-043 4 -4 TransferMot:60:1200dpi