SC Tables
D037/D038/D040/D041 4-14 SM Appendix
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
303 D AC charge output error [Y]
The measured voltage is not proper when BCU measures the charge
output for each color.
Disconnected or broken high voltage cable
Defective or not installed PCDU
Defective HVPS-CB board
- -
1. Check or replace the connectors.
2. Replace the PCDU for the affected color.
3. Replace the HVPS-CB board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
Color development motor error
The motor LOCK signal is not detected for more than two seconds
while the motor START signal is on.
Color development motor slip due to an increase in the torque
325 D
1. Adjust the torque properly by replacing or cleaning the
development unit.
2. Replace the development motor: CMY if the load torque is normal.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
360 D TD sensor (Vt high) error 1: K
361 D TD sensor (Vt high) error 1: M
362 D TD sensor (Vt high) error 1: C
363 D TD sensor (Vt high) error 1: Y