SC Tables
SM Appendix 4-55 D037/D038/D040/D041
Appendix:
Service Call
Conditions
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
-
-
1. Replace the RAM DIMM.
2. Replace the controller board.
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
833
CTL
C
Self-diagnostic error 8: Engine I/F ASIC
[0F30]
[0F31]
ASIC (Mandolin) for system control could not be detected. After the
PCI configuration, the device ID for the ASIC could not be checked.
Replace the VBCU
[0F41]
ASIC (Mandolin) for system control could not be detected. After the
PCI configuration, the device ID for the ASIC could not be checked.
Replace the VBCU
[50B1]
Could not initialize or read the bus connection.
Check for loose connections at the mother board.
Replace the mother board
[50B2]
Value of the SSCG register is incorrect.
Check for loose connections at the mother board.
Replace the mother board
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
838
CTL
B
Self-diagnostic error: Clock Generator
A verification error occurred when
settings data was read from the
clock generator via the I2C bus.
Defective clock generator
Defective I2C bus
Defective CPU port for the I2C
bus
Replace Controller
No. Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
839
CTL
C
USB NAND Flash ROM error
[9101]
The ID of the USB NAND Flash ROM cannot be read.
Defective controller board
Rev. 09/03/2010
⇒